Difference between revisions of "User:CRImier/Pinecil Hardware Debugging"
Jump to navigation
Jump to search
m (Fxc moved page Pinecil Hardware Debugging to User:CRImier/Pinecil Hardware Debugging without leaving a redirect: Orphaned stub) |
|||
(3 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
This page is work-in-progress and is user-contributed content. | This page is work-in-progress and is user-contributed content. | ||
= | {| class="wikitable" style="margin:auto" | ||
|- | |||
= | ! Issue !! Cause/Symptoms !! Possible Solutions | ||
|- | |||
|rowspan="3"|Pinecil doesn't power on at all | |||
|Faulty PSU | |||
|Check your PSU with another tool or a multimeter | |||
|- | |||
|Faulty cable | |||
| | |||
* Check cable with another device | |||
* Use a different cable | |||
|- | |||
|Internal problem with power | |||
|Use different kind of PSU (if you're using a barrel jack one, try a Type-C one, and vice-versa) | |||
|- | |||
| Pinecil shuts down when connected to a Type-C PSU and trying to request a higher voltage (Title needs a bit more clarification) | |||
|Out-of-date firmware | |||
|Update firmware - factory firmware has quite a few USB-PD problems, which the newer firmwares fix. See the [https://github.com/Ralim/IronOS/blob/master/Documentation/Flashing.md#pinecil-pine64 update documentation on GitHub] | |||
|- | |||
| Pinecil randomly resets when touching solder or doing other things | |||
= | | Using PinePower or some other non-grounded PSU | ||
|This is likely to be a "lack of grounding" problem. When using Pinepower, you can unplug the figure-8 AC cable plug (on the back), rotate it 180 degrees and plug it back in - this tends to remedy the problem [https://github.com/Ralim/IronOS/issues/975 (insights)] | |||
|- | |||
| Doesn't power on after applying 24V to the barrel jack | |||
|Damaged USB chip | |||
|The FUSB302 might have gotten damaged and shorted an internal power rail | |||
* Use a hot air gun to remove the FUSB from the board. You can leave the iron without the FUSB302 IC, or you can find and buy a replacement. | |||
* Without the FUSB IC present, you will lose USB-PD compatibility - the Type-C jack will not power your Pinecil with a C-to-C cable, or from a PD-capable PSU with attached type-C cable (laptop PSUs) | |||
* You will still have USB QC support without the FUSB IC, and all the other features will keep working! | |||
|- | |||
|rowspan="3"|Pinecil tip heats up too much, starts to glow and [REDACTED] | |||
| Heats up when plugged in, without pressing any buttons | |||
| Likely a FET failure - the FET can be replaced. by using a hot air station or a soldering iron. | |||
|- | |||
| Heats up after pressing the button | |||
| Likely to be bad soldering of the thermocouple amplifier IC. Resoldering the thermocouple amplifier should fix this problem. | |||
|- | |||
|colspan="2"| '''Either way, you will want to replace the tip after it's heated up to the point of glowing, as the surface coating is likely to have gotten compromised.''' | |||
|} | |||
= Debugging instructions = | = Debugging instructions = | ||
Line 35: | Line 49: | ||
== Checking whether the MCU and main power rails are alive == | == Checking whether the MCU and main power rails are alive == | ||
- DFU mode REDACTED | - DFU mode REDACTED | ||
[[Category:Pinecil]] |
Latest revision as of 19:37, 20 February 2023
This page is work-in-progress and is user-contributed content.
Issue | Cause/Symptoms | Possible Solutions |
---|---|---|
Pinecil doesn't power on at all | Faulty PSU | Check your PSU with another tool or a multimeter |
Faulty cable |
| |
Internal problem with power | Use different kind of PSU (if you're using a barrel jack one, try a Type-C one, and vice-versa) | |
Pinecil shuts down when connected to a Type-C PSU and trying to request a higher voltage (Title needs a bit more clarification) | Out-of-date firmware | Update firmware - factory firmware has quite a few USB-PD problems, which the newer firmwares fix. See the update documentation on GitHub |
Pinecil randomly resets when touching solder or doing other things | Using PinePower or some other non-grounded PSU | This is likely to be a "lack of grounding" problem. When using Pinepower, you can unplug the figure-8 AC cable plug (on the back), rotate it 180 degrees and plug it back in - this tends to remedy the problem (insights) |
Doesn't power on after applying 24V to the barrel jack | Damaged USB chip | The FUSB302 might have gotten damaged and shorted an internal power rail
|
Pinecil tip heats up too much, starts to glow and [REDACTED] | Heats up when plugged in, without pressing any buttons | Likely a FET failure - the FET can be replaced. by using a hot air station or a soldering iron. |
Heats up after pressing the button | Likely to be bad soldering of the thermocouple amplifier IC. Resoldering the thermocouple amplifier should fix this problem. | |
Either way, you will want to replace the tip after it's heated up to the point of glowing, as the surface coating is likely to have gotten compromised. |
Debugging instructions
Screen FPC solder joint debugging
- REDACTED
Checking whether the MCU and main power rails are alive
- DFU mode REDACTED